curvefit.com. Guide to nonlinear regression.Try our software free for 30 days.StatMate leads you step by step through power and sample size calculations.InStat is a less cumbersome alternative to typical heavy-duty statistical programs. With InStat, even a statistical novice can analyze data in just a few minutes.Prism is a powerful combination of basic biostatistics, curve fitting and scientific graphing in one comprehensive program.GraphPad Software. Data analysis and biostatistics resources.


spa

Table of contents
Intro to regression
Nonlinear regression
Curve fitting with Prism
Interpreting the results
Comparing two curves
Distributions of best-fit values
Radioligand binding


s

Introduction
Law of mass action
Ligand depletion
Nonspecific binding
Radioactivity theory
Calculator
Saturation binding
Competitive binding
Kinetics of binding
Dose-response curves
Enzyme kinetics
Standard curves
More information
Search curvefit.com


curvefit.com was created by GraphPad Software, Inc. Send comments or questions to the author of these pages, Dr. Harvey Motulsky, president of GraphPad Software.

In April 2003, GraphPad released Prism 4 and published Fitting Models to Biological Data using Linear and Nonlinear Regression. This book includes all the information that comprises curvefit.com, and much more. You can read this book as a pdf file.

Ligand depletion

In many experimental situations, you can assume that a very small fraction of the ligand binds to receptors (or to nonspecific sites). In these situations, you can assume that the free concentration of ligand is approximately equal to the concentration you added. This assumption vastly simplifies the analysis of binding experiments, and the standard analysis methods depend on this assumption.

In other situations, a large fraction of the ligand binds to the receptors (or binds nonspecifically). This means that the concentration of ligand free in the solution does not equal the concentration you added. The discrepancy is not the same in all tubes or at all times. The free ligand concentration is depleted by binding.

Many investigators use this rule of thumb: If less than 10% of the ligand binds, don't worry about ligand depletion; if more than 10% of the ligand binds, you have three choices:

   Change the experimental conditions. Increase the reaction volume without changing the amount of tissue. The problem with this approach is that it requires more radioligand, which is usually very expensive.
   Measure the free concentration of ligand in every tube. This is possible if you use centrifugation or equilibrium dialysis, but is quite difficult if you use vacuum filtration to remove free radioligand.

Use analysis techniques that adjust for the difference between the concentration of added ligand and the concentration of free ligand. The next few chapters explain several such methods.